Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Bio Mater ; 7(2): 950-960, 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38303668

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), or coronavirus disease 2019 (COVID-19), is still spreading worldwide; therefore, the need for rapid and accurate detection methods remains relevant to maintain the spread of this infectious disease. Electrochemical immunosensors are an alternative method for the rapid detection of the SARS-CoV-2 virus. Herein, we report the development of a screen-printed carbon electrode immunosensor using a hydroxyapatite-gold nanocomposite (SPCE/HA-Au) directly spray-coated with the immobilization receptor binding domain (RBD) Spike to increase the conductivity and surface electrode area. The HA-Au composite synthesis was optimized using the Box-Behnken method, and the resulting composite was characterized by UV-vis spectrophotometry, TEM-EDX, and XRD analysis. The specific interaction of RBD Spike with immunoglobulin G (IgG) antibodies was evaluated by differential pulse voltammetry and electrochemical impedance spectroscopy methods in a [Fe(CN)6]4-/3- solution redox system. The IgG was detected with a detection limit of 0.0561 pg mL-1, and the immunosensor had selectivity and stability of 103-122% and was stable until week 7 with the influence of storage conditions. Also, the immunosensor was tested using real samples from human serum, where the results were confirmed using the chemiluminescent microparticle immunoassay (CMIA) method and showed satisfactory results. Therefore, the developed electrochemical immunosensor can rapidly and accurately detect SARS-CoV-2 antibodies.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Carbon/chemistry , Gold/chemistry , SARS-CoV-2 , Biosensing Techniques/methods , COVID-19/diagnosis , Immunoassay/methods , Antibodies, Viral , Immunoglobulin G , Electrodes , Hydroxyapatites
2.
Biosens Bioelectron ; 220: 114892, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36413914

ABSTRACT

The detection of dopamine in the presence of norepinephrine using nafion-coated boron doped diamond (Nafion-BDD) electrodes was presented. An increase current signal for dopamine could be observed at around 0.75 V using Nafion-BDD, while a change in the current signal of norepinephrine that appears at similar potential was not observed. This might be due to electronegativity of the norepinephrine that is not positive enough to be attracted towards the nafion membrane, albeit neutral enough to pass through the membrane and undergo electrochemical oxidation. An optimization process including accumulation time of dopamine inside the nafion layer, solution of the pH, and nafion thickness was conducted to exploit the difference electrochemical behavior between those two catecholamines at the Nafion-BDD. Using an accumulation time of 300 s, solution pH of 7, and nafion thickness of 1.1 µm, dopamine's LOD was found to be 0.966 µM. Low-interference signal of norepinephrine to the dopamine could be observed with an excellent %recovery of dopamine in 5% range when the concentration of norepinephrine was 10 times lower compared to dopamine concentration.


Subject(s)
Biosensing Techniques , Norepinephrine , Dopamine , Boron , Electrodes
3.
RSC Adv ; 13(1): 220-227, 2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36605667

ABSTRACT

Activated carbon (AC) is an effective and inexpensive adsorbent material for dye removal, but it cannot always be used repeatedly. Furthermore, the adsorbed dyes with toxicity usually remain on its surface. In this study, a thermal air oxidation process was used to modify the surface of AC and decompose adsorbed methylene blue (MB). The behavior of this process on spent AC was investigated using TGA-DTA, while the degradation of MB before and after the regeneration process was analyzed using a carbon, hydrogen, nitrogen, sulfur (CHNS) analyzer. It was discovered that thermal air oxidation could promote the formation of oxygenated functional groups on AC produced from steam-activated carbon coconut shell (SACCS), which when treated at 350 °C (denoted as SACCS-350), demonstrated an adsorption capacity 2.8 times higher than the non-air-oxidized AC (SACCS). The key parameters for the MB adsorption of SACCS and SACCS-350, such as kinetics, equilibrium, and thermodynamics, were compared. Moreover, the SACCS-350 could be reused at least 3 times for the adsorption of MB. Based on these results, thermal air oxidation treatment could successfully improve the adsorption performance of AC and regenerate spent AC through a reasonable and environmentally friendly process compared to other regeneration methods.

4.
J Hazard Mater ; 415: 125635, 2021 08 05.
Article in English | MEDLINE | ID: mdl-33770681

ABSTRACT

Nano-rod-shaped niobium oxide with a deformed orthorhombic structure (ortho-Nb2O5) is first demonstrated as a selective adsorbent to remove cationic dyes wastewater. Ortho-Nb2O5 quickly adsorbs methylene blue (MB) with much greater capacity than reported inorganic adsorbents. Furthermore, ortho-Nb2O5 has a stronger affinity to cationic dye than anionic dye because cation exchange is involved in the adsorption process. The dye molecule adsorbed onto ortho-Nb2O5 can be degraded entirely under UV light irradiation because of its photocatalytic properties. Moreover, the regenerated ortho-Nb2O5 shows high reusability for use in additional adsorption processing. As described herein, new insights into the use of ortho-Nb2O5 as a photocatalytically regeneratable adsorbent for wastewater treatment are presented.

SELECTION OF CITATIONS
SEARCH DETAIL
...